Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Secured Trading Service
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (15)
  • Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
  • Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
  • Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
  • Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
  • Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
  • Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
DW45
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
MCCB
Poles Number
3p ,4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CE, CB, CCC
Items
Ns Moulded Case Circuit Breaker(MCCB)
Rated Current
2000A to 6300A
Grade Quality
A Grade
Warranty Time
2 Years
Service
OEM and ODM Service
Delivery Time
2 Weeks
Transport Package
Standard Export Packing
Specification
CE, ROHS, ISO9001
Trademark
BSD
Origin
China, Huangshan
HS Code
8536200000
Production Capacity
10000PCS/Month

Product Description

Product Description

DW45 (TGW45) series Intelligent Air Circuit Breaker is extensively used as the main switch in the low voltage distribution switchboard of rated voltage of 400V and 690V, rated current of 630A to 6300A, 50HZ or 60HZ. Its function is to control and protect the electr ical circuit from damage and prevent power equipments from harm of overload, under-voltage, short circuit and single phase earth etc. Provide with intelligent protecting function and precise selective protection, breaker can enhance the dependability of power supply and avoid unwanted power cut. It comply with IEC60947-2 standard.

Feature of DW45 Intelligent Air Circuit Breaker(ACB):

- Rated AC current: 630A-6300A

- Number of poles: 3 pole and 4 pole

- Two Types: draw-out type and fixed type

- Short-circuit breaking capacity: 80KA-120KA

- Rated Voltage: under AC690V

- Operation type: manual operation, auto operation

- Trip types: Intelligent controller, under voltage instant (or time delay type) trip and shunt trip

- Intelligent controller types: L type (basic type), M type (Standard type), and H type (communication type)

- Standards: IEC60947-2, GB14048.2

 

Normal Working Conditions of DW45 intelligent Air Circuit Breaker(ACB):

- The ambient temperature of our intelligent circuit breaker should be within -5 to +40. The average temperature should not be more than +35(except for customized designs)

- The altitude should be below 2000M.

- The relative humidity should not be more than 50% at +40 , the upper temperature limit. At lower temperatures, higher humidity is allowed e.g 90% at 20. Dew that is formed during temperature variation should be eliminated, to increase its durability.

- Pollution garde: class 3

- The following have an installation grade of IV: main circuit, absent voltage release coil, power transformer primary coil. Other auxiliary circuits and controls have a mounting grade of III

- The circuit breaker should be installed according to the manual. The vertival tilt angle should not exceed 5 degrees.

- If the air circuit breaker is installed in a small compartment of the switch board, the protection grade is up to IP40. If it is then fitted with a door frame, the protection grade is up to IP54.

 

Structure Characteristics of DW45 Intelligent Air Circuit Breaker(ACB):

- DW45 intelligent air circuit breaker can be of a fixed type and draw-out type. The fixed type air circuit breaker is installed within a special drawer to become a draw-out type breaker. Our circuit breaker consists of a contact system, and arc-extinguishing system, operating mechanism, current transformer, intelligent controller and auxiliary switches, secondary plug and socket, under voltage and shunt releases. The draw-out type air circuit breaker has a holder that is made up of right and left side plates, base, beams, etc.

- Contact system

It adopts integrated contact system, including the main contact and arc contact. The contact is made of high quality material, which does not lead to high temperatures even when it is breaking short circuit current. The contact system is of parallel connection, which reduces the electrical-dynamic repulsion force and improves electric steadiness. The distance between the moving and static contact is much greater than 18mm as it is required. This is in full compliance with safety requirements.

Note: "Trip" lock device for breaker is optional, the isolating switch is a necessary

- Arc-extinguishing chamber

Each pole has an arc-extinguishing chamber, which works to separate and isolate each electrode. The arc extinguishing chamber is enclosed within the insulating base of the intelligent air circuit breaker, which enforces the mechanical strength of arc extinguishing chamber wall and avoids breakage when it is breaking a large short circuit current.

- Operating mechanism: manual and automatic mechanism

The operating mechanism is located at the front of the intelligent air circuit breaker. It adopts a five-link, trip free structure. It is available with energy storage. The breaker can be closed instantly. The stored energy can be released by a hand-operated button or closing electromagnet. The motor driven mechanism is integrated: consists of an energy storage shaft and main shaft which are connected with concave and convex parts. It is easy to assemble or disassemble.

- Intelligent controller

- Drawer holder

The drawer holder of our intelligent air circuit breaker consists of right and left guide rail side plates, base and cross arm. A boosting device and an indicator are fitted to the base. A static contact auxiliary circuit is installed at the top of the drawer holder. The bridge type main circuit contacts are safety separated by a plate at the front.

- Three positions of the breaker in the drawer

--"ON" position: Both the main circuit and the auxiliary circuit are connected. The separation plate is open.

--"Test" position: the main circuit is disconnected. The separation plate is closed. Only the auxiliary circuit is connected. Tests can be made in this mode.

--"OFF" position: both the main and the auxiliary circuits are disconnected. The safe separation plate is closed.


Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p

Specification of Air Circuit Breaker

 

Type

                             DW45-1000                             

DW45-2000 DW45-3200 DW45-4000 DW45-6300

Frame rated

current Inm (A)

1000 2000 3200 4000 6300
Number of poles 3,4 3,4 3,4 3,4 3,4
Rated current In (A)

200,400,630,

800,1000

630,800,1000,

1250,1600,2000

             

 

 

2000,2500,3200                                      

 

2000,2500,3200,4000 4000,5000,6300
Icu (kA)O-CO 400V 42 80 100 100 120
690V 25 50 65 65 80
Ics (kA)O-CO-CO 400V 30 50 65 65 80
690V 20 40 50 50 70
Icw(kA)O-CO 400V 20 50 65 65/80(MCR) 85/100(MCR)
690V 20 40 50 50/65(MCR) 65/75(MCR)

Rated current

at N-pole In (A)

50%In, 100%In

Inherent making&

breaking

time

23-32ms

Operational performance (operations)

Electric

life

500
Mechanical life Maintenance-free2500 Maintenance 10000

Mounting

mode

Fixed with drawable

Arcing

distance(mm)

0

Intelligent

controller

Standard type(M)                    Telecommunication type (H)


Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p
Acb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4pAcb/MW1/Dw45 Series Air Circuit Breaker with 3200A, 6300A, 3p, 4p

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now